1. Large Ferrous Particles > 60 microns
2. Large Non-Ferrous Particles > 60 Microns
3. Droplets - water or other fluid droplets
4. Ferrous Index - checking for small wear particles
5. % Water Estimate
6. Dielectric Number
If the trends and alarms show a problem, then more sophisticated instruments are used. The software allows for trending and reporting with alarm limits that can be added or standard ones used from the software. Values can be exported for use with other software like CSI, LIMS etc.
My Opinion:
I have come across many portable systems in recent years. Some units provide one or two absolute measurement types with varying testing times using up to 500ml of oil. The OIlview look at the basics to be encountered in used oil which can influence the life of your machines at an affordable price in a small portable format with quick testing times.
Read more on the Oilview.

Comments